Conventional Solution

Conventional Solution: The figures above show the turn-off sequence during regular operation and desat condition, respectively. For these tests, di/dt has been controlled by use of R_g = 5.6Ω for regular operation and R_g = 10Ω for fault condition operation.
The turn-off loss is defined as the area under the curve where V_ds and I_ds overlap. 


In the case of a short circuit fault, where I_ds  reaches 2000A the V_ds attains a peak of 1200V (Maximum device rating). Note that the DC Link Voltage was only 500V, in which case the overshoot voltage is 700V!

Where to buy

Definitions:

               I_ds

               V_gs

               V_ds

PERFORMANCE

150kw/25khz - embedded heat pipe

Evaluation Kit Built on 3 Rohm BSM300D12P2E001 Modules with AgileSwitch Stack Electronics

Part Number:AAI3E3-00010
Includes:

3x EDEM3-EconoDual Electrical Master 3

3x ROHM BSM300D12P2E001

3x Current Sensors

1x Mersen Chill Plate

1x Mersen Capacitor Bank,  1100V/740uF

3x Snubber Film Capacitors, 2000V/0.47uF

Device Programmer

Spec Sheet:AAI3E3 Spec Sheet - Coming Soon

200kw/30khz - cold plate

Evaluation Kit Built on 3 Rohm BSM300D12P2E001 Modules with AgileSwitch Electronics

Rest of World
Lead Time: 10 weeks

AgileSwitch Solution

MORE INFORMATION
Part Number:AAI3E3-00003
Includes:

3x EDEM3-EconoDual Electrical Master 3

3x ROHM BSM300D12P2E001

3x Current Sensors

1x Mersen Heat Sink with Embedded Heat Pipes

1x Mersen Capacitor Bank,  1100V/740uF

3x Snubber Film Capacitors, 2000V/0.47uF

Device Programmer

Spec Sheet:AAI3E3 Spec Sheet - Coming Soon

Definitions:

               I_ds

               V_gs

               V_ds

North and South America 

Normal Operation Conditions:

V_dc = 800V

I_ds = 266A 

R_g = 0Ω

Short Circuit Conditions:

V_dc = 500V 

I_ds = 2000A

R_g = 0Ω

Where to buy

ANALOG SIC IPM EVALUATION KITS

Rest of World
Lead Time: 10 weeks

AgileSwitch Solution: The EDEM3 Gate Driver was developed to optimally drive SiC Power Modules at much higher switching frequencies, and incorporates Two-Level Turn-Off, along with patent-pending Multi-Level Shut Down functions. For regular operation, using R_g = 0Ω, the V_ds peak = ~1100V, which equates to an overshoot voltage of 300V. In terms of turn-off losses, the AgileSwitch solution is 50% more efficient than the conventional solution.


In the event of a short circuit, the EDEM3 performs a three-step turn-off with the intermediate steps being 13V and 9V. While R_g = 0Ω, the V_ds peak is ~1000V, showing that the overshoot is only 500V.

North and South America 

Normal Operation Conditions:
V_dc = 800V
I_ds = 266A 

R_g = 5.6Ω

Short Circuit Conditions:

V_dc = 500V 
I_ds = 2000A

R_g = 10.0Ω (DSAT)